Sign In | Join Free | My chinaqualitycrafts.com |
|
Brand Name : HENGFENGYOU
Model Number : GGD, GCK, MNS
Certification : ISO IEC CB COC KEMA SNI SABS CCC
Place of Origin : China
MOQ : 1
Price : 200-20000/piece
Payment Terms : LC T/T
Supply Ability : 5000 piece/year
Delivery Time : 30 days
Packaging Details : wooden case
Type : metal clad
Rated frequency : AC 50Hz (60Hz)
Rated current(A) : 630, 1250, 1600, 2500, 3510, 4000
Customized : OEM/ODM order acceptable
Application : Power transmission or distribution
Product Name : Electrical kyn28 12 switchgear 11kv
Rated Voltage : 3KV, 7.2KV, 12KV optional
Comply standards : DL/T404, IEC298,GB3906
GCS AC 380V 0.4KV Low Voltage Switchgear Complete Set Electrical Distribution Switch Cabinet Switchgear
GCS model AC LV Withdrawable applies to power plant, substation industrial enterprise, as motive force in AC 50/60Hz, rated working voltage 380/415V, rated current 3150A and below distribution system. For transferring power energy, distributing and controlling of lightning and distribution. High breaking capacity, rated short time current will reach 50kA. Flexible circuit scheme, convenient combination, novel structure.
This product conforms to IEC60439 LV Switchgear and controlgear, GB7251 LV Switchgear and controlgear etc.
Executive standard:
GB7251 Low voltage complete set switchgear and control device
GB3906-2006 3.6kV~40.5kV AC metal enclosed switchgear and control device
Working Condition
1.Ambient temperature should not be more than -25℃ but not less than 40℃; 24-hour average temperature should not be more than +35℃.
2.The altitude of installation site should not exceed 2000m in the case of indoor installation;
3.The relative humidity of ambient air should not exceed 50% at +40℃; a higher relative humidity is allowed under conditions of low temperature (e.g. 90% at +20℃). The condensation may be generated under the influence of temperature variation, which should be taken into consideration.
4.The vertical inclination of equipment should not exceed 5°.
5.The equipment should be installed in the places without violent vibration and impulse and as well the places without corrosion to the electric components
no | name | unit | data |
1 | rated voltage | kv | 3, 6,10 |
2 | ratd current | A | 630,1000,1250,1600,2000,2500,3150 |
3 | rated frequency | HZ | 50 |
4 | rated short circuit drop out current(effective value) | KA | 20.25; 31.5; 40 |
5 | rated thermo stable current( peak value) | KA | 20.25; 31.5; 40 |
6 | rated dynamic current( peak value) | KA | 40; 80; 100 |
7 | rated power frequency withsand voltage(1min) | KV | inter-electrode and earth 42; inter -fractures 48 |
8 | ratd thunder impulse withstand voltage | KV | inter-electrode and earth 75; inter -fractures 85 |
9 | rated thermo stable time | KV | 4 |
10 | degree of protection | IP2X | |
11 | externam dimension(WXDXH) | MM | 1100x1200x2650( can design according to demand) |
Rated isolation voltage | To 1000V |
Rated operational voltage | To 600V |
Rated frequency | 50 /60 Hz |
Rated impact withstand voltage | 8 kV |
Rated voltage of auxiliary circuit | AC380, 220V,DC 220V |
Over voltage degree | III |
Pollution degree | 3 |
Rated current | 4000A |
Horizontal busbar rated current | 4000A |
Vertival busbar rated current | 2000, 1000A |
Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.
![]() |